RCBO 30mA Type A — 1P+N Residual Current Circuit Breaker | UKCA Certified
£10.65 – £11.93Price range: £10.65 through £11.93
RCBO Type A | 1P+N | 6A–40A | 30mA | Electromagnetic | 6kA | UKCA Certified
RCBO 30mA Type A — 1P+N Residual Current Circuit Breaker
The DGB1NLE-A is a 1-pole + neutral (1P+N) Type A Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combining MCB and RCD functionality in a single compact module. This Type A RCBO detects both AC sinusoidal and pulsating DC residual currents — making it the preferred choice for modern domestic installations and a requirement under BS 7671 (18th Edition) Amendment 2 for circuits supplying EV chargers, heat pumps, solar inverters and equipment with electronic converters.
Available in current ratings from 6A to 40A at 30mA sensitivity, the DGB1NLE-A provides individual circuit protection without the risk of nuisance tripping on unrelated circuits. With a 6kA breaking capacity and Type C trip characteristic, it replaces the need for a separate MCB and RCD on each circuit. Manufactured to IEC/EN 61009-1, this RCBO is designed for 35mm DIN rail mounting and is compatible with all consumer units and distribution boards.
Key Features
- Combined MCB + RCD in one device — overcurrent, short-circuit and earth leakage protection in a single module
- Type A residual current detection — detects AC sinusoidal and pulsating DC earth leakage faults
- Required by BS 7671 Amendment 2 for EV charger, heat pump and inverter circuits
- 1P+N configuration — protects both line and neutral in a compact 2-module width
- 30mA sensitivity — personal protection level on every individual circuit
- Current ratings: 6A, 10A, 16A, 20A, 25A, 32A, 40A — covers all standard domestic circuit sizes
- 6kA breaking capacity — meets BS 7671 requirements for typical domestic fault levels
- Type C trip characteristic — suitable for general-purpose circuits and moderate inrush loads
- Eliminates nuisance tripping — each circuit independently protected
- Test button for periodic RCD functional testing
- 35mm DIN rail mounting — fits all consumer units and standard distribution boards
Technical Specification
| Standard | IEC/EN 61009-1 |
| Product model | DGB1NLE-A |
| Device type | RCBO (MCB + RCD combined) |
| RCD type | Type A |
| Rated residual current (IΔn) | 30mA |
| Number of poles | 1P+N |
| Rated current (In) | 6A, 10A, 16A, 20A, 25A, 32A, 40A |
| Rated voltage | 240V AC (230V) |
| Breaking capacity (Icn) | 6kA |
| Trip characteristic | Type C (5–10In) |
| Trip form | Thermal-magnetic + electromagnetic RCD |
| Rated frequency | 50/60 Hz |
| Module width | 36mm (2 modules) |
| Protection grade | IP20 |
| Mechanical life | 20,000 operations |
| Electrical life | 10,000 operations |
| Max wiring capacity | 25mm² |
| Max tightening torque | 3.5 Nm |
| Installation method | 35mm DIN rail |
| Operating temperature | -25°C to +40°C |
Compliance & Certification
- Manufactured to IEC/EN 61009-1
- UKCA certified
- CE certified | CB scheme
- Compliant with BS 7671 (18th Edition) Type A requirements for EV, heat pump and inverter circuits
- Tagged: EV — suitable for EV charging circuit protection when combined with appropriate upstream devices
Installation Notes
This RCBO must be installed by a qualified electrician in accordance with BS 7671 (18th Edition). Always isolate the supply before installation. The RCBO occupies 2 modules (36mm) on the DIN rail. Connect the line to the L terminal and the neutral to the N terminal. The neutral connection is essential for the RCD element to operate. The test button should be operated at least quarterly. For EV charging circuits, BS 7671 Regulation 722.531.3.101 requires Type A RCD protection as a minimum — this RCBO satisfies that requirement. For smooth DC fault protection, pair with a Type B RCD upstream or specify a Type B RCD instead.
- Switch disconnector designed to safely isolate the main circuit
- DIN rail mounted — fits standard 35mm DIN rail for easy panel installation
- Lockable in the Off position for lockout/tagout safety compliance
- Contact status indicator window for clear visual on/off indication
- Upper and lower incoming — flexible cable entry from either direction
- Matches DGB1 series MCBs and RCBOs for consumer unit builds
- Suitable for residential, commercial and industrial installations
- Available in 1P, 2P, 3P and 4P configurations, 32A to 125A
- Rated to IEC 60947-3 — certified to KEMA, CE, SEMKO and CB standards
- IP20 protection grade with 10,000 electrical / 20,000 mechanical operation life
| Brand | Terelec |
| SKU / Model | DGG1-125-1P-100A |
| Current Rating | 100A |
| Frame Current | 125A |
| Voltage Rating | AC 230V (1P) / AC 400V (3P, 4P) |
| Number of Poles | 1 Pole |
| IP Rating | IP20 |
| Mounting | 35mm DIN Rail |
| Terminal Capacity | 35mm² (at 100A) |
| Terminal Type | Fixed with screw |
| Incoming Method | Upper and Lower |
| Lockable | Yes |
| Indicator Window | Contact status indication |
| Electrical Life | 10,000 operations |
| Mechanical Life | 20,000 operations |
| Rated Insulation Voltage | 690V |
| Rated Frequency | 50/60 Hz |
| Pollution Class | Class III |
| Storage Temperature | -25°C to +70°C |
| Installation Altitude | ≤2000m |
| Standards | IEC 60947-3 |
| Certifications | KEMA, CE, SEMKO, CB |
Download the product datasheet and supporting documents below:
To request a datasheet for a specific product, please contact us.
Related products
10kA MCB – High Breaking Capacity Miniature Circuit Breaker
In stock
2-Pole RCD 30mA Type AC — Residual Current Device | UKCA Certified
In stock
2/4-Pole RCD 30mA Type A — Residual Current Device | UKCA Certified
In stock
DC MCB 10kA 1-Pole 300V — DC Miniature Circuit Breaker for Solar PV
In stock
Metal Garage Consumer Unit | UKCA Certified
In stock
Type 2 SPD 20kA 1P+N – Surge Protection Device for Consumer Units | UKCA Certified
In stock
| Poles | 1-Pole |
|---|

Reviews
Clear filtersThere are no reviews yet.