2-Pole RCD 30mA Type AC — Residual Current Device | UKCA Certified
£10.92 – £11.74Price range: £10.92 through £11.74
RCD Type AC | 2P | 25A/40A/63A | 30mA/100mA/300mA | UKCA Certified | IEC 61008
2-Pole RCD 30mA Type AC — Residual Current Device
The DGL2-63-AC is a 2-pole Type AC Residual Current Device (RCD) providing earth leakage protection for single-phase domestic and commercial electrical circuits. Designed to detect AC sinusoidal residual currents, this RCD disconnects the supply when earth fault current exceeds the rated sensitivity — protecting people against electric shock and reducing the risk of electrical fires caused by insulation faults.
Available in 25A, 40A and 63A current ratings with 30mA, 100mA and 300mA sensitivity options, the DGL2-63-AC covers a wide range of applications from personal protection (30mA) to fire protection (100mA and 300mA). Manufactured to IEC/EN 61008-1 and designed for 35mm DIN rail mounting, it is compatible with all consumer units and split-load distribution boards. The 2-pole configuration is suitable for single-phase TN-S, TN-C-S and TT earthing systems commonly found in UK installations.
Key Features
- Type AC residual current detection — protects against AC sinusoidal earth leakage faults
- Available sensitivities: 30mA (personal protection), 100mA and 300mA (fire protection)
- Current ratings: 25A, 40A and 63A — covers domestic and light commercial load requirements
- 2-pole (single-phase) configuration — suitable for split-load consumer units and sub-boards
- Electromagnetic trip mechanism — operates independently of supply voltage for fail-safe protection
- Test button — allows periodic functional testing as required by BS 7671
- 35mm DIN rail mounting — fits all consumer units and standard distribution boards
- IP20 finger-safe protection — suitable for indoor panel installation
- Trip indicator — visual confirmation of RCD trip status
Technical Specification
| Standard | IEC/EN 61008-1 |
| Product model | DGL2-63-AC |
| RCD type | Type AC |
| Rated residual current (IΔn) | 30mA, 100mA, 300mA |
| Number of poles | 2P (single-phase L+N) |
| Rated current (In) | 25A, 40A, 63A |
| Rated voltage | 240V AC (230V) |
| Rated insulation voltage (Ui) | 500V |
| Rated conditional short-circuit current (Inc) | 6kA (with upstream MCB) |
| Trip mechanism | Electromagnetic |
| Rated frequency | 50/60 Hz |
| Module width | 36mm (2 modules) |
| Pollution level | 2 |
| Protection grade | IP20 |
| Mechanical life | 20,000 operations |
| Electrical life | 10,000 operations |
| Max wiring capacity | 25mm² |
| Max tightening torque | 3.5 Nm |
| Installation method | 35mm DIN rail |
| Operating temperature | -25°C to +40°C |
Compliance & Certification
- Manufactured to IEC/EN 61008-1
- UKCA certified
- CE certified | CB scheme
- Suitable for use in installations compliant with BS 7671 (18th Edition IET Wiring Regulations)
Installation Notes
This RCD must be installed by a qualified electrician in accordance with BS 7671. Always isolate the supply before installation. The RCD must be protected upstream by an appropriately rated MCB or fuse. The test button should be operated at least quarterly to confirm the RCD trips correctly. Type AC RCDs detect sinusoidal AC fault currents only — for circuits supplying equipment with electronic components that may produce pulsating DC fault currents (e.g. EV chargers, inverters, IT equipment), a Type A or Type B RCD should be specified instead.
Related products
10kA MCB – High Breaking Capacity Miniature Circuit Breaker
In stock
2/4-Pole RCD 30mA Type A — Residual Current Device | UKCA Certified
In stock
4-Way Consumer Unit 100A Main Switch + SPD | UKCA Certified
In stock
8-Way Consumer Unit 100A Main Switch + SPD | UKCA Certified
In stock
RCBO 30mA Type AC — 1P+N Residual Current Circuit Breaker | UKCA Certified
In stock

Reviews
Clear filtersThere are no reviews yet.