RCBO 30mA Type A — 1P+N Residual Current Circuit Breaker | UKCA Certified
£10.65 – £11.93Price range: £10.65 through £11.93
RCBO Type A | 1P+N | 6A–40A | 30mA | Electromagnetic | 6kA | UKCA Certified
RCBO 30mA Type A — 1P+N Residual Current Circuit Breaker
The DGB1NLE-A is a 1-pole + neutral (1P+N) Type A Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combining MCB and RCD functionality in a single compact module. This Type A RCBO detects both AC sinusoidal and pulsating DC residual currents — making it the preferred choice for modern domestic installations and a requirement under BS 7671 (18th Edition) Amendment 2 for circuits supplying EV chargers, heat pumps, solar inverters and equipment with electronic converters.
Available in current ratings from 6A to 40A at 30mA sensitivity, the DGB1NLE-A provides individual circuit protection without the risk of nuisance tripping on unrelated circuits. With a 6kA breaking capacity and Type C trip characteristic, it replaces the need for a separate MCB and RCD on each circuit. Manufactured to IEC/EN 61009-1, this RCBO is designed for 35mm DIN rail mounting and is compatible with all consumer units and distribution boards.
Key Features
- Combined MCB + RCD in one device — overcurrent, short-circuit and earth leakage protection in a single module
- Type A residual current detection — detects AC sinusoidal and pulsating DC earth leakage faults
- Required by BS 7671 Amendment 2 for EV charger, heat pump and inverter circuits
- 1P+N configuration — protects both line and neutral in a compact 2-module width
- 30mA sensitivity — personal protection level on every individual circuit
- Current ratings: 6A, 10A, 16A, 20A, 25A, 32A, 40A — covers all standard domestic circuit sizes
- 6kA breaking capacity — meets BS 7671 requirements for typical domestic fault levels
- Type C trip characteristic — suitable for general-purpose circuits and moderate inrush loads
- Eliminates nuisance tripping — each circuit independently protected
- Test button for periodic RCD functional testing
- 35mm DIN rail mounting — fits all consumer units and standard distribution boards
Technical Specification
| Standard | IEC/EN 61009-1 |
| Product model | DGB1NLE-A |
| Device type | RCBO (MCB + RCD combined) |
| RCD type | Type A |
| Rated residual current (IΔn) | 30mA |
| Number of poles | 1P+N |
| Rated current (In) | 6A, 10A, 16A, 20A, 25A, 32A, 40A |
| Rated voltage | 240V AC (230V) |
| Breaking capacity (Icn) | 6kA |
| Trip characteristic | Type C (5–10In) |
| Trip form | Thermal-magnetic + electromagnetic RCD |
| Rated frequency | 50/60 Hz |
| Module width | 36mm (2 modules) |
| Protection grade | IP20 |
| Mechanical life | 20,000 operations |
| Electrical life | 10,000 operations |
| Max wiring capacity | 25mm² |
| Max tightening torque | 3.5 Nm |
| Installation method | 35mm DIN rail |
| Operating temperature | -25°C to +40°C |
Compliance & Certification
- Manufactured to IEC/EN 61009-1
- UKCA certified
- CE certified | CB scheme
- Compliant with BS 7671 (18th Edition) Type A requirements for EV, heat pump and inverter circuits
- Tagged: EV — suitable for EV charging circuit protection when combined with appropriate upstream devices
Installation Notes
This RCBO must be installed by a qualified electrician in accordance with BS 7671 (18th Edition). Always isolate the supply before installation. The RCBO occupies 2 modules (36mm) on the DIN rail. Connect the line to the L terminal and the neutral to the N terminal. The neutral connection is essential for the RCD element to operate. The test button should be operated at least quarterly. For EV charging circuits, BS 7671 Regulation 722.531.3.101 requires Type A RCD protection as a minimum — this RCBO satisfies that requirement. For smooth DC fault protection, pair with a Type B RCD upstream or specify a Type B RCD instead.