2-Pole RCD 30mA Type AC — Residual Current Device

The DGL2-63-AC is a 2-pole Type AC Residual Current Device (RCD) providing earth leakage protection for single-phase domestic and commercial electrical circuits. Designed to detect AC sinusoidal residual currents, this RCD disconnects the supply when earth fault current exceeds the rated sensitivity — protecting people against electric shock and reducing the risk of electrical fires caused by insulation faults.

Available in 25A, 40A and 63A current ratings with 30mA, 100mA and 300mA sensitivity options, the DGL2-63-AC covers a wide range of applications from personal protection (30mA) to fire protection (100mA and 300mA). Manufactured to IEC/EN 61008-1 and designed for 35mm DIN rail mounting, it is compatible with all consumer units and split-load distribution boards. The 2-pole configuration is suitable for single-phase TN-S, TN-C-S and TT earthing systems commonly found in UK installations.

Key Features

  • Type AC residual current detection — protects against AC sinusoidal earth leakage faults
  • Available sensitivities: 30mA (personal protection), 100mA and 300mA (fire protection)
  • Current ratings: 25A, 40A and 63A — covers domestic and light commercial load requirements
  • 2-pole (single-phase) configuration — suitable for split-load consumer units and sub-boards
  • Electromagnetic trip mechanism — operates independently of supply voltage for fail-safe protection
  • Test button — allows periodic functional testing as required by BS 7671
  • 35mm DIN rail mounting — fits all consumer units and standard distribution boards
  • IP20 finger-safe protection — suitable for indoor panel installation
  • Trip indicator — visual confirmation of RCD trip status

Technical Specification

Standard IEC/EN 61008-1
Product model DGL2-63-AC
RCD type Type AC
Rated residual current (IΔn) 30mA, 100mA, 300mA
Number of poles 2P (single-phase L+N)
Rated current (In) 25A, 40A, 63A
Rated voltage 240V AC (230V)
Rated insulation voltage (Ui) 500V
Rated conditional short-circuit current (Inc) 6kA (with upstream MCB)
Trip mechanism Electromagnetic
Rated frequency 50/60 Hz
Module width 36mm (2 modules)
Pollution level 2
Protection grade IP20
Mechanical life 20,000 operations
Electrical life 10,000 operations
Max wiring capacity 25mm²
Max tightening torque 3.5 Nm
Installation method 35mm DIN rail
Operating temperature -25°C to +40°C

Compliance & Certification

  • Manufactured to IEC/EN 61008-1
  • UKCA certified
  • CE certified | CB scheme
  • Suitable for use in installations compliant with BS 7671 (18th Edition IET Wiring Regulations)

Installation Notes

This RCD must be installed by a qualified electrician in accordance with BS 7671. Always isolate the supply before installation. The RCD must be protected upstream by an appropriately rated MCB or fuse. The test button should be operated at least quarterly to confirm the RCD trips correctly. Type AC RCDs detect sinusoidal AC fault currents only — for circuits supplying equipment with electronic components that may produce pulsating DC fault currents (e.g. EV chargers, inverters, IT equipment), a Type A or Type B RCD should be specified instead.

Additional information
Current Rating
Sensitivity100mA, 300mA, 30mA
Reviews (0)
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “2-Pole RCD 30mA Type AC — Residual Current Device | UKCA Certified”

Your email address will not be published. Required fields are marked *

1 2 3 4 5
1 2 3 4 5
1 2 3 4 5